A decade box for precision trimming and power sinking.
Project overview
As an individual who enjoys power electronics, I am regularly annoyed by two unrelated challenges:
- Critical voltage references and associated resistive networks are less accurate than required.
- Testing power circuits requires a configurable assortment of static loads to sink power.
My custom decade box solves both problems. Rotary switches on the top faceplate provide a selectable resistance from 1Ω to 10MΩ. A separable link at 10kΩ facilitates precision trimming of resistor networks. Banana jacks on the front faceplate connect to an array of 1Ω and 10Ω wire-wound power resistors.
The design files for this project are on Github.
Design and construction
The decade box schematic is simple. A resistor bridges adjacent selectable contacts on each rotary switch. Each center contact is then wired to the first contact of the next decade. Each rotary switch therefore controls how many series connected resistors are in-circuit.
The output of the 1kΩ decade and the input of the 10kΩ decade is where I’ve split the resistor series. This way the 1Ω-10kΩ range and 10kΩ-10MΩ range can be used simultaneously to trim-up and trim-down, respectively. The optimal resistor size to be trimmed is around 3kΩ; 1Ω in series trims 3kΩ up by 0.03%, 10MΩ in parallel trims 3kΩ down by 0.03%.
Resistor trimming demonstration
Anxious to trim some resistors, I grabbed a couple 22kΩ resistors and put them in series as a voltage divider. I connected my power supply and set the knob to 5V. My meter reads 2.522V. Without touching the power supply, can I trim this divider so that my meter reads 2.5V exactly?
The first step is to wire my decade box into the circuit. As mentioned earlier, the low-resistance range goes in series and the high-resistance range goes in parallel. I’ll trim the bottom resistor of the two; since they’re both 22kΩ the choice is arbitrary.
With the decade box now in circuit, the meter reading is virtually unchanged at 2.523V. Because the reading is higher than the desired 2.5V, I start by setting the parallel trim resistor to 1MΩ. This drops the meter reading down to 2.495V.
Now that the reading is too low, I can set the series trim resistor to 82Ω to bring the meter reading back up to exactly 2.5V.
1MΩ in parallel and 82Ω in series, those are standard resistor values. I disconnected the decade box and plugged them in… and the meter reads 2.499V. Not bad!
Power sinking test
The cast aluminum box the wire-wound power resistors are glued to is 5” x 8” x 2”. I hadn’t bothered calculating how much power the box could sink before starting a fire. I figured a test would be more exciting.
The picture above is the box dissipating 90W. With my desk fan blowing across the back, the steady-state temperature is 70C. My power dissipation and steady-state temperature measurements are in the table below. The box thermal resistance is about 0.55 C/W and it takes approximately 5 minutes to reach steady-state.
| Current (A) | Power (W) | Temperature (°C) |
|---|---|---|
| 1.6 A | 25.6 W | 35 °C |
| 2.0 A | 40.0 W | 43 °C |
| 2.4 A | 57.6 W | 53 °C |
| 2.8 A | 78.4 W | 63 °C |
| 3.0 A | 90 W | 70 °C |
Inductance measurements
A critical limitation of decade boxes is that the internal wiring can add a lot of inductance. Circuits which operate at high frequencies (ex. filters/feedback networks) will potentially behave differently with the decade box in circuit compared to using a single resistor.
How much inductance does my decade box have? I don’t have an LCR meter to measure the inductance directly, so I did it the old fashioned way with a sine wave generator and an oscilloscope.
With my sine wave generator set to 200mVpp and a load of 10Ω, I swept the sine wave frequency until the probe at the decade box input measured twice the voltage measured at the output. At 2.8MHz, the inductance of the decade box is therefore 980nH.
I then repeated the same measurement for the 10x 1Ω wire-wound power resistors in series. The result was 2.4uH. Considering these are wire-wound resistors, this was less than I would have guessed.
Considering that 10Ω + 2.4uH has a time constant of 240ns, this load box could be used for dynamic loading as well as static. For example, this box could test the step response of power converters with microsecond-scale response speeds. Just what I needed!